C-AM-0600I Модуль CIB, 5×AI/DI, 1×AI, модуль аналоговых входов и учета электроэнергии, IP55
C-AM-0600I Модуль CIB, 5×AI/DI, 1×AI, модуль аналоговых входов и учета электроэнергии, IP55
C-AM-0600I Модуль CIB, 5×AI/DI, 1×AI, модуль аналоговых входов и учета электроэнергии, IP55
Характеристики и описание

Основной

ПроизводительTeco
Страна производительЧехия
СостояниеНовое

Пользовательские характеристики

DI5x DI/counter
DI/AI5x DI/AI
AI1x interface for TacoSetter Tronic flowmeter
COM1x CIB slave
SENSORInterface for TacoSetter Tronic flowmeter
C-AM-0600I - module on the CIB Common Installation Bus®, contains 5 universal inputs and 1 special interface for connecting a turbine-free TacoSetter Tronic flowmeter. Universal inputs can be configured for measurement resistance temperature sensors, Tension, current can be configured as an interface for reading pulses from energy meters, eg electricity meters, gas meters, etc. The TacoSetter Tronic flowmeter interface contains 2 outputs. The first output is the analog signal from the flow meter and the second is the signal from the integrated thermometer.
DI5x DI/counter
DI/AI5x DI/AI
DO
AI1x interface for TacoSetter Tronic flowmeter
AO
COM1x CIB slave
SENSORInterface for TacoSetter Tronic flowmeter
COM - System buses
CIB - Common Installation Bus (R): Installation I/O bus1x CIB slave
Parameter des Temperatursensors
Temperature - Sensor typePt1000
Temperature - Measurement range-90°C ÷ 320°C
Temperature - Measurement error<2% of range
Temperature - Conversion time500 μs
Lighting sensor parameters
Lighting - Sensor typePhotodiode BPW21
Lighting - Measuring range0 lx ÷ 50000 lx
Lighting - Measurement error<5% of range
Lighting - Temperature coefficient± 0.1% of full scale / ° C
Lighting - Linearity of measurements± 0.2% of full scale
Lighting - Repeatability under steady state conditions0.5% of full scale
Power supply
Supply voltage, tolerances24/27 V DC from CIB bus
Maximum power input< 0,5 W
Power supply from CIB - maximum current consumption (mA)25 mA
Power supply from CIB - internal protectionNo
Size and weight
Weight approx.150 g
Product dimensions (width x height x depth)74 × 125 × 39 mm
Operating conditions, product standards
Product standardČSN EN 60730-1 ed. 2:2001 (mod IEC 60730-1:1999)
Protection class of electrical objectII, according to ČSN EN 61140: 2003 (idt IEC 61140: 2001)
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989)IP54
Operating areasNormal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005)
Degree of pollution1, according to ČSN EN 60664-1 ed.2:2008 ( idt IEC 60664-1:2007)
Overvoltage category installationII, according to EN 60664-1 ed_2: 2008 (idt IEC 60641-1: 2007)
Type of deviceOutdoor
Working positionVertical
Type of operation (operating frequency)Continuous
Ambient operating temperatures-10 °C to + 55 °C
Operating relative humidityfrom 10 % up to 95 % without condensation
Operating atmospheric pressuremin. 70 kPa (<3,000 m above sea level)
Storage temperatures–25 °C to +70 °C
Electromagnetic compatibility, Mechanical endurance
Electromagnetic compatibility / EmissionB, according to EN 55022: 1999 (mod CISPR22: 1997)
Electromagnetic compatibility / Immunitymin. according to ČSN EN 60730-1 ed.2: 2001
Sinusoidal vibration endurance10 Hz to 57 Hz, amplitude 0,075 mm, 57 Hz to 150 Hz, acceleration 1 G (Fc test according to EN 60068-2-6: 1997 (idt IEC 68-2-6: 1995), 10 cycles per axis.)
Packaginng, transportation, storage
DescriptionThe module is packed in a paper box. This documentation is also part of the package. The outer packaging is carried out according to the scope of the order and the method of transport in a transport package provided with labels and other data necessary for transport. The product must not be exposed to direct weather conditions during transport and storage. Malting of the product is only allowed in clean rooms without conductive dust, aggressive gases and vapors. The most suitable storage temperature is 20 ° C
Installation
Assembly descriptionThe C-RI-0401I module is mounted in a vertical position on the support surface with the cable gland facing downwards. We recommend a place protected from direct sunlight, the sensor is not intended for measuring direct sunlight. Installation of the assembly (basic module and possibly peripheral modules) is performed according to TXV 004 13.
Connection
Connection descriptionThe combined module is implemented as a CIB bus module, which provides communication and power supply to the module. The CIB bus can have any topology and branching up to a distance of 500 m and up to 32 units on one CIB branch. The CIB bus master is the FOXTROT base unit or module, for example CF-1141. Further information can be found in the manual Peripheral modules on the CIB TXV 004 13.
Connection of power and system communication2 wire cable 4.5 - 7mm, PG9 bushing
Module connectionDescription of signals red (yellow) wire + CIB black (green) wire - CIB
Module operation
CommissioningThe module is operated, set and diagnosed from the MOSAIC programming environment or other parameterization software. The module is ready for operation after connecting the supply voltage and the CIB bus. The HW address is indicated on the label on the module.
Module diagnosticsThe basic diagnostics is performed internally and the result is available in the relevant registers of the Mosaic environment.
Maintenance
DescriptionThe module does not require any maintenance under general installation conditions. The operations in which a part of the module has to be dismantled must always be carried out with the supply voltage disconnected.
NoticeBecause the module contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling the removed cover. It is not allowed to directly touch the printed circuit boards without protective measures !!!
Warranty
GenerallyWarranty and complaint conditions are governed by the Terms and Conditions of Teco a.s.
NoticeYou must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change.

C-AM-0600I Модуль CIB, 5×AI/DI, 1×AI, модуль аналоговых входов и учета электроэнергии, IP55

Под заказ, 40 дней
Код: TXN 133 50
от 7 920 
Способы оплаты
Наложенный платеж
Нова Пошта, Самовывоз
Оплата на счет
IBAN UA383253650000002600101565149
Способы доставки
Нова Пошта — от 70 грн
Самовывоз
Условия возврата
Возврат товара в течение 14 дней за домовленістю
Любимые товары покупателей
Чат