DATAKOM DFC-0124 Power Factor Controller, 128x64 B&W display,144x144mm, 24steps + RS485 + SVC
DATAKOM DFC-0124 Power Factor Controller, 128x64 B&W display,144x144mm, 24steps + RS485 + SVC
DATAKOM DFC-0124 Power Factor Controller, 128x64 B&W display,144x144mm, 24steps + RS485 + SVC
Характеристики та опис

Основні

ВиробникDatakom

Користувальницькі характеристики

Вага0.718
РізноменклатуриТовар
Картинкиhttp://www.controllers4generators.com/upload/iblock/c28/bjo9pnyqd6t01jv4tmxhi6ybcz7m301b/DATAKOM-DFC-0124_1.resize2.jpg, http://www.controllers4generators.com/upload/iblock/e88/4lisjq611hzytybr1hsfv5b22aykhgz1/DATAKOM-DFC-0124_2.resize2.jpg
ТипНомендуриЗапас
DATAKOM DFC-0124 SVC ENABLED REACTIVE POWER CONTROLLER The DFC-0124 is an advanced, precision 24 step power factor control and metering device offering unrivalled internet monitoring capabilities in a standard 144x144mm panel mount enclosure. The unit has various models offering 12-18-24 step outputs. Outputs can be selected as contactor or static switch drivers in blocks of 6. Every output is capable of driving single or three phase, capacitor or reactor. The unit is very simple to install and commission thanks to the automatic setup and connection correction features. Vast communication capabilities are embedded to the unit. It does not require any external component. The unit itself is a web page and can be opened through any browser for remote monitoring. The central monitoring feature can monitor thousands of meters on one screen. Thanks to its SVC outputs it can match the exact target pf value independently of capacitor rating selections. SVC SYSTEM: SVC stands for “Static Var Compensation”. The unit has 3 SVC outputs which are duty cycle controlled PWMs that control 3 reactors with a precision of 1000 steps. Thus the controller is able to supply almost any required reactive power on each phase, enabling matching the exact required PF, independently from capacitor bank selection. FEATURES: • Easy to use with user friendly menu system • Easy automatic setup under load • Automatic correction of connection faults • Measurement period: 10-100ms adjustable • Reactive correction in 20ms • 24-18-12 step output options • All steps can drive capacitors/thyristors • All steps can be mono or tri-phased • Always exact correction with SVC outputs • 0.5% measurement accuracy, true RMS • 32 bit power measurement accuracy • Low current compensation capable (3mA) • Graphic LCD display, 128x64 pixels • Harmonic measurements of all voltages and currents • Harmonic distortion display (31 harmonics) • Oscilloscope, waveform display • Ready for remote monitoring over GPRS and LAN • Geo-location over GSM • Remote parameter adjustment • Remote step control enabled • Long term data recording on USB flash memory • Battery backed-up real time clock • 250 event records with date-time • User configurable display screens • Adjustable alarm limits • Configurable relay outputs • Voltage transformer ratio for MV applications • Password protected front panel programming • Reduced panel depth • Sealed front panel (IP65 with gasket) COMMUNICATIONS: • GSM-SMS sending • e-mail sending • Central Monitoring through IP • Web monitoring • Web programming • Free configuration & monitoring software • Modbus RTU RS-485 • Modbus TCP/IP • SNMP • TCP/IP server • TCP/IP client • UDP • SMTP TECHNICAL SPECIFICATIONS Power Supply Input: 85 to 270V AC 50 - 60Hz nominal (± 10%) Power Consumption: < 15 VA Measurement Input Range: Voltage: 5 - 300 V AC (L-N) 10 - 520 V AC (L-L) Current: 0.005 - 5.5 A AC Frequency: 30 - 100 Hz Accuracy: Voltage: 0.5%+1digit Current: 0.5%+1 digit Frequency: 0.2%+1 digit Power(kW,kVAr): 1.0%+2digit Power factor: 0.5%+1digit Measurement Range: CT range: 5/5A to 10’000/5A VT range: 0.1/1 to 5000.0/1 kW range: 0.1 kW to 6.5MW Voltage burden: < 0.1VA per phase Current burden: < 0.5VA per phase Number of step outputs: 24 Relay Outputs: 5A @ 250V AC Static Contactor Outputs: 50mA @ 12V DC SVC Outputs: 50mA @ 12V DC Temperature Input: PT100 sensor or switch (optional) Operating Temperature: -20°C to +70°C (-4 to +176 °F). Maximum humidity: 95% non-condensing. Degree of Protection: IP 65 (Front with gasket) IP 30 (Back) Enclosure: Non-flammable, ROHS compliant Installation: Flush mounting with rear brackets Dimensions: 164x164x69mm (WxHxD) Panel Cutout: 140x140mm Weight: 700 gr EU Directives: 2006/95/EC (LVD) 2004/108/EC (EMC) Norms of reference: EN 61010 (safety) EN 61326 (EMC) WE DO NOT SHIP THIS DATAKOM PRODUCT TO USA AND CANADA

DATAKOM DFC-0124 Power Factor Controller, 128x64 B&W display,144x144mm, 24steps + RS485 + SVC

В наявності