promo_download_app_android_2023
Натисніть знайти для пошуку
DATAKOM DKG-105 Automatic start mains failure control panel for generators (AMF)
DATAKOM DKG-105 Automatic start mains failure control panel for generators (AMF)
Характеристики та опис

Основні

ВиробникDatakom

Користувальницькі характеристики

Вага0.25
РізноменклатуриТовар
ТипНомендуриЗапас
ШтрихКод2601057506989
DKG-105 AUTOMATIC MAINS FAILURE UNIT The DKG-105 automatic mains failure unit is a microprocessor based digital unit offering all functions needed for the automatic control of a genset. The unit fits into a standard 72x72mm panel meter opening and offers a very cost effective and space saving solution for the basic genset control. In automatic mode, the unit monitors 3 phases of the mains voltage and controls the automatic starting, stopping and load transfer of the generator. Once the generator is running, the device monitors the internal protections and external fault inputs. DKG-105 provides a full set of digitally adjustable timers and threshold levels. Also the relay configuration is programmable, enabling the control of various types of engines, including gasoline engines. The programs may be modified by the customer via pushbuttons on the unit, and do not require an external unit. FEATURES: Automatic engine starting and stopping Gas engine support Automatic mains failure monitoring Automatic load transfer Automatic shutdown on fault condition Test mode available Survives cranking dropouts Digital engine run-hours display Provision for energize to stop, preheat & choke outputs Mains phases voltage limits checking Generator phase voltage limits checking Delayed overspeed and underspeed alarm Digitally adjustable low & high mains voltage limits Digitally adjustable low & high generator voltage limits Digitally adjustable underspeed & overspeed limits Digitally adjustable delay for speed alarm Digitally adjustable timers Digital display of mains & generator voltages Digital display of generator frequency Plug-in connection system for easy replacement Low cost Small dimensions Standard panel dimensions, (72x72mm) TECHNICAL SPECIFICATIONS: Mains voltage: 277VAC (Ph-N) Mains frequency: 50/60Hz. Power System Type: TN or TT. Alternator voltage: 277VAC (Ph-N) Alternator frequency: 0-100Hz. Measurement Category: CAT II DC Supply Range: 9 to 33 VDC. 4.0 – 33 VDC while cranking Current consumption: 60 mADC typical (AUTO mode, mains OK) 200 mADC max. (Relay outputs open) Total DC Current Output Rating: 10ADC. Total AC Current Output Rating: 10AAC. Current Rating for each Output Terminal: 10ARMS. Operating temperature range: -20?C (-4?F) to 70 ?C (158?F). Storage temperature range: -30?C (-22?F) to 80 ?C (176?F). Maximum humidity: 95% non-condensing. Dimensions: 78 x 78 x 50mm (WxHxD) Mounting opening dimensions: 68 x 68mm minimum. Weight: 200 g (approx.) Accuracy: Phase voltages: 2% + 1v Generator frequency: +/- 0.5 Hz Case Material: Flame Retardant High Temperature ABS/PC (UL94-V0, 110?C) WE DO NOT SHIP THIS PRODUCT TO USA AND CANADA

DATAKOM DKG-105 Automatic start mains failure control panel for generators (AMF)

В наявності
6 200 
Способи оплати
Післяплата
Нова Пошта
Способи доставки
Нова Пошта — від 60 грн
Умови повернення
Повернення товару впродовж 14 днів за домовленістю
Інші товари продавця
Подібні товари інших продавців
Дивіться також
Новинки в категорії електрогенератори
Чат